ARCO CHEMICAL COMPANY, DIV OF ATLANTIC RICHFIELD -- ISOPROPYL ALCOHOL (99%) -- 6810-00-286-5435
===================== Product Identification ===================== Product ID:ISOPROPYL ALCOHOL (99%) MSDS Date:11/03/1993 FSC:6810 NIIN:00-286-5435 === Responsible Party === Company Name:ARCO CHEMICAL COMPANY, DIV OF ATLANTIC RICHFIELD Address:1500 MARKET STREET Box:7258 City:PHILADELPHIA State:PA ZIP:19101 Country:US Info Phone Num:800-321-7000 Emergency Phone Num:215-353-8300,CHEMTREC 800-424-9300 CAGE:3D253 === Contractor Identification === Company Name:ARCO CHEMICAL COMPANY, DIV OF ATLANTIC RICHFIELD Address:1500 MARKET STREET Box:7258 City:PHILADELPHIA State:PA ZIP:19101 Country:US Phone:215-353-8300,CHEMTREC 800-424-9300 CAGE:3D253 Company Name:PACKAGING SERVICES INC Address:472 SHANK RD Box:875 City:PEARLAND State:TX ZIP:77581 Country:US Phone:713-485-1457 CAGE:9V846 Company Name:PRILLAMAN CHEMICAL CORP Address:201 SUBBURBAN DR Box:1606 City:SUFFOLK State:VA ZIP:23434-1606 Country:US Phone:804-539-7401 CAGE:0G5T1 ============= Composition/Information on Ingredients ============= Ingred Name:ISOPROPYL ALCOHOL (SARA III) CAS:67-63-0 RTECS #:NT8050000 Fraction by Wt: 99% Other REC Limits:NONE SPECIFIED OSHA PEL:400 PPM/500 STEL ACGIH TLV:400 PPM/500STEL;9192 ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE-EYE:MAY CAUSE SEVERE EYE IRRITATION. INGESTION:MAY BE SLIGHT HEALTH HAZARD IF INGESTED IN LARGE QUANTITIES. SKIN:NO SIGNIFICANT HEALTH HAZARD FROM ABSORPTION OR EXPOSURE. CHRONIC-PROLONGED EXPOS URE CAN BE IRRITATING TO MUCOUS MEMBRANES. Explanation of Carcinogenicity:THIS CHEMICAL IS NOT LISTED AS HAVING ANY EVIDENCE OF BEING CARCINOGENIC. Effects of Overexposure:PROLONGED OVEREXPOSURE OF VAPORS MAY CAUSE COUGHING, DIZZINESS, SHORTNESS OF BREATH, AND INTOXICATION. Medical Cond Aggravated by Exposure:MATERIAL OR ITS EMISSIONS MAY AFFECT MUCOUA TISSUE AND/OR AGGRAVATE MUCOUS MEMBRANE DYSFUNCTION. ======================= First Aid Measures ======================= First Aid:INHALATION:REMOVE VICTIM TO FRESH AIR IMMEDIATELY. GIVE OXYGEN OR PERFORM CPR. OBTAIN MEDICAL ATTENTION. EYE:IMMEDIATELY RINSE WITH CLEAN WATER FOR 20-30 MIN. OBTAIN MEDICAL ATTENTION. SKIN:WASH SKIN THOROUGHLY WITH MILD SOAP/WATER. FLUSH WITH LUKE WARM WATER FOR 15 MIN. IF STICKY, USE WATERLESS CLEANER FIRST. INGESTION:GIVE LUKEWARM WATER (PINT). DO NOT INDUCE VOMITING. GET MEDICAL ATTENTION. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:53.0F,11.7C Autoignition Temp:Autoignition Temp Text:750F Lower Limits:2 Upper Limits:12.7 Extinguishing Media:ALCOHOL TYPE FOAM, DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY, WATER FOG Fire Fighting Procedures:DO NOT ENTER FIRE AREA WITHOUT PROPER PROTECTION. FIGHT FIRE FROM SAFE DISTANCES. USE WATER SPRAY/FOG FOR COOLING. EXTINGUISHING FIRE BY DILUTION MAY NOT WORK. Unusual Fire/Explosion Hazard:RELEASES FLAMMABLE VAPOR BELOW AMBIENT TEMPS. CAN BURN OR EXPLODE WHEN MIXED W/AIR. VAPORS ARE HEAVIER THAN AIR & MAY TRAVEL ALONG GROUND & 'FLASH BACK'. ================== Accidental Release Measures ================== Spill Release Procedures:EXTREMELY FLAMMABLE LIQUID. FIRE/EXPLOSION HAZARD. EVACUATE/LIMIT ACESS. WEAR PROPER PROTECTION. STOP RELEASE. STOP FLOW TO SEWERS/PUBLIC WATERS. SOAK UP SMALL SPILL WITH INERT SOLIDS. USE SUITABLE DI SPOSAL CONTAINERS. BLANKET LARGE SPILLSWITH FOAM. Neutralizing Agent:NONE ====================== Handling and Storage ====================== Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINERS AWAY FROM HEAT,SPARKS,OPEN FLAME & STRONG OXIDIZING AGENTS. EMPTY CONTAINERS MAY CONTAIN FLAMMABLE VAPOR RESIDUE. Other Precautions:USE NON-SPARKING TOOLS. VENT CAREFULLY BEFORE REMOVING CLOSURE. GROUND CONTAINERS W/NATIONAL ELECTRICAL CODE EQUIPMENT BEFORE TRANSFERRING MATERIAL. MATERIAL MAY ATTACK SOME FORMS OF PLASTIC, ALUMINUM , RUBBER AND COATINGS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:IF EXPOSURE EXCEEDS THE PEL/TLV, USE NIOSH/MSHA APPROVED RESPIRATORY PROTECTION EQUIPMENT AS SPECIFIED IN THE NIOSH/OSHA 1981 OCCUPATIONAL HEALTH GUIDELINES FOR CHEMICAL HAZARDS. Ventilation:NO SPECIAL VENTILATION BEYOND THAT FOR NORMAL COMFORT IS USUALLY REQUIRED TO MEET EXPOSURE STANDARDS. Protective Gloves:NOT NORMALLY CONSIDERED A SKIN HAZARD. Eye Protection:CHEMICAL SPLASH GOGGLES & FACESHIELD Other Protective Equipment:EMERGENCY EYE WASH STATION & SAFETY SHOWER SHOULD BE AVALIABLE IN THE IMMEDIATE VICINITY OF ANY POTENTIAL EXPOSURE. Work Hygienic Practices:WASH HANDS BEFORE EATING, DRINKING, SMOKING, OR USING TOILET FACILITIES. WASH CONTAMINATED CLOTHING BEFORE REUSE. Supplemental Safety and Health ISOLATE, VENT, DRAIN, WASH & PURGE SYSTEMS OR EQUIPMENT BEFORE MAINTENANCE OR REPAIR. REMOVE ALL IGNITION SOURCES, CHECK ATMOSPHERE FOR EXPLOSIVENESS & OXYGEN DEFICIENCIES. USE ADEQUATE PERSONAL PROTE CTIVE EQUIPMENT. OBSERVE PRECAUTIONS PERTAINING TO CONFINED SPACE ENTRY. ================== Physical/Chemical Properties ================== HCC:F2 NRC/State Lic Num:NONE Boiling Pt:B.P. Text:180F,82C Melt/Freeze Pt:M.P/F.P Text:-127F,-88C Vapor Pres:33 MM Vapor Density:2.1 Spec Gravity:0.78 pH:N/AP Solubility in Water:COMPLETE Appearance and Odor:LIQUID, MEDICINAL ODOR ANALOGOUS TO RUBBING ALCOHOL, CLEAR, COLORLESS ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES ALUMINUM METALS, NITROFORM, STRONG OXIDIZING AGENTS, SULFURIC ACID. Stability Condition to Avoid:HEAT, SPARKS, OPEN FLAME, OTHER IGNITION SOURCES, OXIDIZING CONDITIONS. Hazardous Decomposition Products:INCOMPLETE COMBUSTION MY YIELD CARBON MONOXIDE AND OTHER TOXIC GASES. Conditions to Avoid Polymerization:WILL NOT OCCUR. ==================== Disposal Considerations ==================== Waste Disposal Methods:CONTAMINATED PRODUCT/SOIL/WATER MAY BE RCRA HAZARDOUS WASTE. LANDFILL SOLIDS AT PERMITTED SITES. USE REGISTERED TRANSPORTERS. BURN CONCENTRATED LIQUIDS IN SYSTEMS COMPATIBLE WITH WATER SOLUBLE WASTE. AVOID FLAMEOUTS. ASSURE EFFLUENT COMPLYSW/REGS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.