NATIONAL REFRIGERANTS INC -- REFRIGERANT 12 -- 6830-00-106-1656
=====================  Product Identification  =====================

Product ID:REFRIGERANT 12
MSDS Date:06/01/1988
FSC:6830
NIIN:00-106-1656
=== Responsible Party ===
Company Name:NATIONAL REFRIGERANTS INC
Address:89 WATER ST
City:BRIDGETON
State:NJ
ZIP:08302-2545
Country:US
Info Phone Num:609-455-4555
Emergency Phone Num:609-455-4555/800-424-9300 CHEMTREC
Preparer's Name:T. NAPRAVA, DR. OF Q.C.
CAGE:4J994
=== Contractor Identification ===
Company Name:NATIONAL REFRIGERANTS INC
Address:661 KENYON AVE
Box:City:BRIDGETON
State:NJ
ZIP:08302
Country:US
Phone:800-262-0012/215-698-6620
CAGE:4J994

=============  Composition/Information on Ingredients  =============

Ingred Name:DICHLORODIFLUOROMETHANE  (SARA III)
CAS:75-71-8
RTECS #:PA8200000
Fraction by Wt: 100%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9192
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ozone Depleting Chemical:1

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL RAT) IS 1000 MG/KG
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:TEMPORARY NERVOUS SYSTEM
    DEPRESSION WITH ANAESTHETIC EFFECTS, TEMPORARY ALTERATION OF THE
    HEART'S ELECTRICAL ACTIVITY WITH IRREGULAR PULSE, PALPITATIONS OR
    IRREGULAR PULSE, ASPHYXIATION DUE TO E XCLUSION OF OXYGEN. SKIN
    PERMEATION APPEARS UNLIKELY. THERE ARE NO REPORTS OF SKIN
    SENSITIZATION.
Explanation of Carcinogenicity:NONE OF THE CHEMICALS IN THIS PRODUCT IS
    LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:EYES: MILD IRRITANT. SKIN:NOT IRRITATING,
    HOWEVER LIQUID CONTACT CAN CAUSE FROSTBITE. INHALATION: DIZZINESS,
    HEADACHE, CONFUSION, INCOORDINATION, LOSS OF CONSCIOUSNESS, DEATH.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF HEART
    DISORDERS MAY BE AT INCREASED RISK FROM EXPOSURE.

=======================  First Aid Measures  =======================

First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER.SEE DOCTOR.
    SKIN:FLUSH WITH WATER.TREAT FOR FROSTBITE IF NECESSARY.
    INHALATION:REMOVE TO FRESH AIR.GIVE CPR/OXYGEN IF NEEDED.SEE
    DOCTOR. INGESTION:SEE DOCTO R IF NECESSARY.     NOTE TO
    PHYSICIAN:BECAUSE OF POSSIBLE DISTURBANCE OF CARDIAC RYTHM,
    CATECHOLAMINE DRUGS, SUCH AS EPINEPHRINE, SHOULD BE USED WITH
    SPECIAL CAUTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NOT FLAMMABLE
Extinguishing Media:AS APPROPIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
    FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
    SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:CYLINDERS MAY RUPTURE UNDER FIRE
    CONDITIONS. FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTION OF
    HAZARDOUS DECOMPOSITION PRODUCTS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VENTILATE AREA, ESPECIALLY LOW PLACES WHERE
    HEAVY VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES. USE SCBA FOR LARGE
    SPILLS.
Neutralizing Agent:NONE APPLICABLE FOR THIS MATERIAL

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTILATED
    AREA. PROTECT FROM PHYSICAL DAMAGE, HEAT AND IGNITION SOURCES. KEEP
    CONTAINERS CLOSED. DO NOT HEAT ABOVE 125 F.
Other Precautions:AVOID BREATHING VAPORS AND LIQUID CONTACT WITH SKIN
    OR EYES. USE ONLY IN WELL VENTILATED AREAS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NO RESPIRATORY PROTECTION NORMALLY REQUIRED. USE
    SCBA IF LARGE RELEASE OCCURS.
Ventilation:MECHANICAL (GENERAL) VENTILATION. LOCAL EXHAUST SHOULD BE
    USED WHEN LARGE AMOUNTS ARE RELEASED.
Protective Gloves:LINED BUTYL GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:SAFETY SHOES.
Work Hygienic Practices:STANDARD WORK HYGENIC PRACTICES.
Supplemental Safety and Health
NATIONAL REFRIGERANTS BUYS BULK QUANTITIES FROM SEVERAL MANUFACTURERS
    FOR REPACKAGE.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:-22F,-30C
Decomp Temp:Decomp Text:>1400F
Vapor Pres:60648
Vapor Density:4.26
Spec Gravity:1.315
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUIFIED GAS WITH FAINT ETHEREAL ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS LIKE POWDERED ALUMINUM, MAGNESIIUM,
    ZINC, BERILLIUM, ETC.
Stability Condition to Avoid:HIGH TEMPERATURES AND OPEN FLAMES
Hazardous Decomposition Products:HYDROCHLORIC ACID, HYDROFLUORIC ACID,
    POSSIBLY CARBONYL CHLORIDE AND CARBONYL FLUORIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTACT YOUR LOCAL ENVIRONMENTAL OFFICER.
    RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE FACILITY.
    DISPOSE OF IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND
    LOCAL LAWS AND REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.