EVR-GARD COATINGS CO -- 2200, INDUSTRIAL MAINT ENAMEL -- 8010-00N030428
===================== Product Identification ===================== Product ID:2200, INDUSTRIAL MAINT ENAMEL MSDS Date:05/01/1991 FSC:8010 NIIN:00N030428 === Responsible Party === Company Name:EVR-GARD COATINGS CO Address:16400 GARFIELD AVE City:PARAMOUNT State:CA ZIP:90723 Country:US Info Phone Num:310-531-0131 Emergency Phone Num:310-531-0131 CAGE:5G582 === Contractor Identification === Company Name:EVR-GARD COATINGS CO Address:16400 GARFIELD AVE Box:City:PARAMOUNT State:CA ZIP:90723 Country:US Phone:310-531-0131 CAGE:5G582 ============= Composition/Information on Ingredients ============= Ingred Name:MINERAL SPIRITS. VP: 5.0 @ 77F CAS:64742-47-8 Fraction by Wt: 31.24% OSHA PEL:150 PPM (MFR) ACGIH TLV:150 PPM (MFR) ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:ACUTE: INHAL:IRRIT OF NOSE, THROAT & EYES, DIZZ, WEAKNESS, FATIGUE, NAUS, HDCH. SYMP DISAPPEAR WHEN EXPOSURE CEASES. EYE/SKIN: CNTCT MAY CAUSE IRRIT. CHRONIC: REPORTS HAVE SHOWN THAT REPEATED AND PRLN GD OCCUP OVEREXP TO SOLV CAN CAUSE PERMANENT BRAIN & NERV SYS DMG. Explanation of Carcinogenicity:NOT RELEVANT Effects of Overexposure:INHAL:DIZZ, HDCH. UNCON IN EXTREME CASES. SKIN/EYE: IRRIT. AFFECTED AREA WILL SHOW SIGNS OF REDNESS & RASH IF NOT WASHED WITH SOAPY WATER IMMED. INGEST: IRRIT OF THE RESP TRACT CHARAC BY HDCH, DIZZ, S TAGGERING, CONFUSION & UNCON AND COMA IN EXTREME CASES. Medical Cond Aggravated by Exposure:PROLONGED AND REPEATED CONTACT MAY CAUSE DERMATITIS. ======================= First Aid Measures ======================= First Aid:INHAL: REMOVE PATIENT TO FRESH AIR. EYE: FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MIN. SKIN: REMOVE SOAKED CLOTHING AND WASH SKIN WITH SOAP & WATER THOROUGHLY. SKIN ABSORP: APPLY LOTION OR OIL TO AF FECTED AREA AFTER THOROUGH WASHING. INGEST: DO NOT INDUCE VOMITING CALL PHYSICIAN IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point:105F,41C Lower Limits:1.0 % Extinguishing Media:FOAM, ALCOHOL FOAM, CO2, DRY CHEMICAL, WATER FOG. Fire Fighting Procedures:FIGHT AS VOLATILE LIQ FIRE. CLSD CNTNRS MAY EXPLO WHEN EXPOS TO EXTREME HEAT. KEEP AWAY FROM AREAS EXPOS TO FIRE. WEAR NIOSH/MSHA APPRVD SCBA & FULL (SUPP DATA) Unusual Fire/Explosion Hazard:AVOID APPLIC IN AREAS OF PILOT LIGHT/SPARK/ OTHER IGNIT SORUCES AS VAP MAY ACCUM ON FLOOR & IGNITE.KEEP CNTNRS CLSD TIGHTLY & STORE IN COOL PLACE WHEN NOT USING ================== Accidental Release Measures ================== Spill Release Procedures:ABSORB SPILLED MATERIAL WITH ABSORBENTS, SUCH AS SAWDUST, CLAYS, ETC AND FLUSH SPILL AREA WITH LOTS OF WATER. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:DO NOT STORE NEAR OPEN FLAME/SOURCES OF IGNIT. DO NOT STORE IN HIGH TEMP STORAGE. IN CASE OF FIRE, REMOVE CLOSED CNTNRS FROM AREAS EXPOSED TO FIRE. Other Precautions:EMPTY CNTNRS USUALLY STILL HOLD RESIDUES OF MATERIAL AND VAPOR. THESE MUST BE CONSIDERED HAZARDOUS AND DISPOSED OF IN ACCORDANCE WITH PROPER HANDLING PROCEDURES PRESCRIBED FOR HAZARDOUS CHEMICALS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:THE USE OF NIOSH/MSHA APPRVD RESP IS RECOM WHEN USING SOLV BASED COATINGS. WHEN LEVEL OF SOLV VAPS IS NOT KNOWN/EXCEEDS LEVEL @ WHICH REGULAR RESPS ARE EFTIVE, USE OF NIOSH/MSHA APPRVD RESP SUCH AS TC -19C-NIOSH-MSHA IS HIGHLY RECOMMENDED. Ventilation:PROVIDE ADEQ VENT IN ALL WORKING AREAS AT ALL TIMES. SERIOUS HLTH PROBLEMS COULD RSLT FROM RPTD/PROLNGD EXPOSURES. Protective Gloves:NEOPRENE, BUNA N. Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:USE GLOVES & GOGG TO PROT AGAINST ACCIDENTAL SPLASHING OF LIQ ONTO SKIN/EYES. AVOID PROLONGED CNTCT/OVEREXP.(SUPP DATA) Work Hygienic Practices:STANDARD HYGIENIC PRACTICES MUST BE OBSERVED WHEN HANDLING THIS PRODUCT AND ALL CHEMICALS. Supplemental Safety and Health FIRE FIGHT PROC: PROTECTIVE EQUIPMENT . OTHER PROT EQUIP: PROVIDE ADEQUATE VENTILATION AT ALL TIMES WHEN APPLYING THIS PRODUCT. ================== Physical/Chemical Properties ================== HCC:F4 Boiling Pt:B.P. Text:168F,76C Vapor Pres:SEE INGRED Vapor Density:HVR/AIR Spec Gravity:1.2 (H2O=1) Evaporation Rate & Reference:SLOWER THAN ETHER Solubility in Water:NOT SOLUBLE Appearance and Odor:WHITE AND COLORED PAINTS WITH PAINT THINNER ODOR. ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG ACIDS OR ALKALIS. LONG TERM CONTACT WITH WATER. Stability Condition to Avoid:AVOID OPEN FLAMES, WELDING ARCS OR OTHER HIGH TEMPERATURE SOURCES WHICH INDUCE THERMAL DECOMPOSITION AND FIRE. Hazardous Decomposition Products:THERMAL DECOMPOSITION MAY YIELD CARBON DIOXIDE AND/OR CARBON MONOXIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF ALL WASTES, INCLUDING ABSORBENTS USED TO CLEAN UP SPILLS INTO 55-GAL METAL CONTAINERS AND DISPOSE IN APPROVED DUMPSITE IN ACCORDANCE WITH PRESCRIBED FEDERAL, STATE AND LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.