DUPONT E I DE NEMOURS & CO INC AUTOMOTIVE PRODS D -- 548U IMRON POLYURETHANE ENAMEL TINTS -- 8010-00F003597
===================== Product Identification ===================== Product ID:548U IMRON POLYURETHANE ENAMEL TINTS MSDS Date:01/01/1995 FSC:8010 NIIN:00F003597 === Responsible Party === Company Name:DUPONT E I DE NEMOURS & CO INC AUTOMOTIVE PRODS D Address:BRANDYWINE BLDG 3332 1007 MARKET ST City:WILMINGTON State:DE ZIP:19898-5000 Country:US Info Phone Num:800-441-7515/800-441-3637 Emergency Phone Num:800-441-3637/800-441-7515 Preparer's Name:T R LOUER CAGE:23027 === Contractor Identification === Company Name:DU PONT E I DE NEMOURS & CO FABRICATED PROD DEPT Address:1007 MARKET ST BRANDYWINE BLDG 3332 Box:City:WILMINGTON State:DE ZIP:19898 Country:US Phone:800-441-3637 CAGE:90227 Company Name:TETRA MFG CORP (CAGE CANCELLED) Address:CAGE CANCELLED City:WESTBURY State:NY ZIP:11590 Country:US Phone:NONE CAGE:23027 ============= Composition/Information on Ingredients ============= Ingred Name:FATTY ACIDS, LINSEED OIL, REACTION PRODUCTS POLYMER; ACRYLIC POLYMER *96-3* CAS:96591-17-2 Ingred Name:2-PROPENOIC ACID 2-METHYL-METHYL ESTER, POLYMER W/ETHENYLBENZENE *96-3* CAS:80010-53-3 Ingred Name:ACETIC ACID, ETHYL ESTER, ETHYL ACETATE * 96-3 * CAS:141-78-6 RTECS #:AH5425000 Other REC Limits:400 PPM OSHA PEL:1400 MG/CUM ACGIH TLV:1400 MG/CUM EPA Rpt Qty:5000 LBS DOT Rpt Qty:5000 LBS Ingred Name:LEAD CHROMATE(VI) OXIDE, CR-O4-PB. O-PB; (HUMAN CARCINOGEN BY IARC GROUP-1, ANIMAL CARCINOGEN BY NTP) *96-3* CAS:18454-12-1 RTECS #:OF9800000 Fraction by Wt: 20% OSHA PEL:0.1 MG/CUM ACGIH TLV:0.05 MG/CUM Ingred Name:PROPYLENEGLYCOL MONOMETHYL ETHER ACETATE, 1-METHOXY-2-PROPANOL ACETATE CAS:108-65-6 RTECS #:AI8925000 Ingred Name:TOLUENE (IARC CARC- GROUP 3) *96-3* CAS:108-88-3 RTECS #:XS5250000 Fraction by Wt: 2% Other REC Limits:375 MG/CUM OSHA PEL:100 PPM ACGIH TLV:100 PPM EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:XYLENE, DIMETHYLBENZENE, XYLOL (IARC - GROUP 3) *96-3* CAS:1330-20-7 RTECS #:ZE2100000 Fraction by Wt: 1% Other REC Limits:100 PPM OSHA PEL:100 PPM ACGIH TLV:100 PPM, SKIN EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:INGESTION: GASTROINTESTINAL DISTRESS. INHALATION: MAY CAUSE NOSE & THROAT IRRITATION. OVEREXPOSURE TO SOLVENTS MAY LEAD TO PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. EYES: IRRITATION/BURNING. SKIN: REPE ATED/PROLONGED CONTACT MAY CAUSE IRRITATION W/DISCOMFORT & DERMATITIS. Explanation of Carcinogenicity:SEE INGREDIENTS. Effects of Overexposure:GASTROINTESTINAL DISTRESS, IRRITATION, EYE WATERING, HEADACHES, NAUSEA, DIZZINESS, LOSS OF COORDINATION, BREATHING DIFFICULTY, BURNING, DISCOMFORT ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE TO FRESH AIR. EYES: IMMEDIATELY FLUSH W/PLENTY OF WATER FOR 15 MINS. SKIN: WASH W/SOAP & WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES. ===================== Fire Fighting Measures ===================== Flash Point Method:CC Flash Point:<73F Lower Limits:0.9 Upper Limits:13 Extinguishing Media:WATER SPRAY, FOAM, CO2, DRY CHEMICAL Fire Fighting Procedures:WEAR FULL PROTECTIVE EQUIPMENT W/SCBA. WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE BUILD UP. Unusual Fire/Explosion Hazard:WHEN HEATED >FLASH POINT, EMITS FLAMMABLE VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLOSIVE. FINE MISTS/SPRAYS MAY BE FLAMMABLE AT TEMPS120F. KEEP AWAY FROM HEAT, SPARKS & FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND CONTAINERS WHEN POURING. OBSERVE LABEL PRECAUTIONS. Other Precautions:DON'T SAND, FLAME CUT, BRAZE/WELD DRY COATING W/O A NIOSH/MSHA APPROVED RESPIRATOR/APPROPRIATE VENTILATION. PRESSURE CAN BE GENERATED. DON'T SEAL CONTAINER. AFTER 48 HOURS, MATERIAL MAY BE SEALED & DI SPOSED OF. DON'T BREATHE VAPORS/MISTS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:A PROPERLY FITTED VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA (TC-23C) FOR USE W/PAINTS DURING APPLICATION & UNTIL VAPORS/SPRAY MISTS ARE EXHAUSTED. CONFINED SPACES/SPRAY OPERATIONS: A POSITIV E-PRESSURE, SUPPLIED AIR RESPIRATOR. Ventilation:SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP CONTAMINANTS 1 VOC Grams/Liter:5.1 Evaporation Rate & Reference:LESS THAN ETHER Solubility in Water:MISCIBLE Percent Volatiles by Volume:61-69 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES Stability Condition to Avoid:HEAT, SPARKS, FLAME & OTHER IGNITION SOURCES Hazardous Decomposition Products:CO, CO2, SMOKE ==================== Disposal Considerations ==================== Waste Disposal Methods:DON'T ALLOW MATERIAL TO CONTAMINATE GROUND WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IAW/LOCAL, STATE & FEDERAL REGULATIONS. DON'T INCINERATE IN CLOSED CONTAINERS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.